The software goes error, the message is “Null overturning moment”.

You are here:
  1. Home
  2. FAQ
  3. The software goes error, the…
A

The software goes error, the message is “Null overturning moment”.

Check the value of cohesion, in the calculation of horizontal pressures the software takes into account the cohesive contribution:
sh (z) = sv (z) Ka-2cKa ^ 0.5
sh (z) = horizontal pressure
sv (z) = vertical pressure
Ka = active thrust coefficient
c = cohesion

Permalink